Introduction
The Jianfan Hemoperfutor IFU (Instructions for Use) serves as a critical resource for healthcare professionals using this advanced hemoperfusion device. Designed to filter and purify the blood of patients in need of urgent toxin removal, the device plays a vital role in intensive care units and emergency medical settings. Understanding and strictly following this manual ensures the safety of both patients and operators.
This guide is intended for clinicians, dialysis technicians, and biomedical engineers, providing comprehensive knowledge about the system’s function, safety features, and troubleshooting techniques.
Device Overview
The Jianfan Hemoperfutor is a specialized extracorporeal blood purification device used primarily in cases of poisoning, liver failure, or severe inflammation. It functions by passing the patient’s blood through an adsorption cartridge filled with medically safe adsorbents that remove toxins before returning the blood to the body.
Key Features:
- High-precision flow control
- Compatibility with standard dialysis systems
- User-friendly digital interface
- Disposable and sterilized cartridge design
System Components:
- Main control unit
- Adsorption column
- Tubing system
- Flow and pressure sensors
- Control panel and display
Component | Description |
---|---|
Control Unit | Manages the flow, timing, and data display |
Cartridge | Contains adsorbents for toxin removal |
Tubes | Connect patient to device in a closed loop |
Display | Shows real-time system status and parameters |
Safety Information
Before using the Jianfan Hemoperfutor, it is essential to understand all safety precautions outlined in the IFU. The system should be used only by trained medical personnel.
Ensure the following:
- Device is placed on a stable, dry surface
- No visible damage to components
- All electrical connections are intact
In case of emergency, follow the predefined shutdown process:
- Pause blood flow via control unit
- Clamp tubing to prevent air embolism
- Disconnect power safely
Unboxing and Inspection
Upon receiving the Jianfan Hemoperfutor system, check that all items listed in the packaging checklist are present:
- Main unit
- Cartridge (x1 per treatment)
- Tubing set
- Power cord
- User manual
Carefully inspect each item for any shipping damage. Do not use any damaged components, and report issues to the manufacturer immediately.
Installation and Setup
The setup process should be performed in a sterile, controlled medical environment. Place the machine near the patient’s bedside for easy access to vascular access points.
Steps:
- Plug the device into a grounded power source.
- Attach the cartridge securely into the slot.
- Connect tubing from patient to device inlet and back.
- Prime the system to remove air and ensure fluid continuity.
- Run a self-diagnostic check using the control panel interface.
Priming is essential for preventing air bubbles, which could cause embolism or ineffective treatment.
Operating Instructions
Once installed, the Jianfan Hemoperfutor can be operated using the digital touchscreen panel.
- Start the session by selecting a program based on patient weight and condition.
- Monitor blood flow, typically set between 150–250 mL/min.
- Adjust pressure settings if alarms are triggered.
At the end of the session:
- Stop the device
- Clamp tubing
- Remove cartridge
- Dispose of consumables as per hospital biohazard protocol
Maintenance and Cleaning
Routine maintenance is crucial for the longevity and safe operation of the Jianfan Hemoperfutor.
Daily:
- Wipe surfaces with disinfectant
- Check tubing connectors
Weekly:
- Perform calibration
- Inspect electrical integrity
Monthly:
- Replace non-disposable sensors if worn
- Software update check
Cleaning reusable parts involves disassembling them (if applicable), soaking in hospital-grade sterilizers, rinsing, and drying thoroughly before next use.
Troubleshooting Guide
Common issues and solutions:
Problem | Possible Cause | Recommended Action |
---|---|---|
No power | Power cord loose | Reconnect or replace cord |
Alarm sounds | High pressure detected | Check for blockages or kinks in tubing |
Incomplete flow | Air in circuit | Re-prime system completely |
If problems persist, refer to the manufacturer’s support line listed in the IFU.
Technical Specifications
- Model Number: JF-HP100
- Voltage Requirement: 110–240V AC, 50/60Hz
- Flow Rate Range: 50–300 mL/min
- Operating Temp: 15°C–30°C
- Storage Temp: 5°C–40°C
Warranty and Support
Each Jianfan Hemoperfutor comes with a 1-year manufacturer warranty covering mechanical defects and software failures not caused by user error. For service, contact the authorized distributor or use the customer support hotline.
Appendices
A. Glossary
- Hemoperfusion: Technique of removing toxins from blood
- Adsorbent: Substance used in cartridge to trap toxins
B. Symbol Definitions
- ⚠: Warning
- ✓: Step completed
C. Disposal Guidelines
- Dispose of single-use components in medical waste bins
- Recycle electronics as per local regulations
D. References
- Clinical studies supporting hemoperfusion in toxin management
- WHO guidelines on extracorporeal treatments
This unique and informative guide to the Jianfan Hemoperfutor IFU provides medical professionals with everything they need to use the device confidently and safely. By adhering to these comprehensive instructions, clinicians can ensure optimal performance and patient safety.
Other Articles
www.free worlderorg: The Ultimate Guide to a Money-Free, Sustainable Future
Culaina Grosaina: A Complete Guide to Its Meaning, Origins, and Modern Relevance
Understanding the 3822 Blossom Terrace Erie PA Water Hook Up Diagram: A Complete Homeowner’s Guide